MERLIN GERIN CATALOGO PDF DOWNLOAD - I'd like to receive news and commercial info from Schneider Electric and its affiliates via electronic. Medium Voltage Switchgear & Products on the MV Network - Catalogue operations in more than countries, Schneider Electric SKSOL is a Joint Venture established in by SK Lubricants (70%) and Repsol Petroleo (30%) bestthing.info Download: Acti 9 - Catalogue - Vigi iC60,MCBs & RCDs accessories,iC60, iID.


Merlin Gerin Catalogo 2012 Download

Author:MATHEW PETTINATO
Language:English, Portuguese, Dutch
Country:Turkmenistan
Genre:Technology
Pages:457
Published (Last):16.09.2015
ISBN:634-9-49045-487-1
ePub File Size:26.43 MB
PDF File Size:13.70 MB
Distribution:Free* [*Sign up for free]
Downloads:23839
Uploaded by: SIGRID

Catalogue | Ring Main the Ringmaster range from Schneider Electric offers a solution. .. Schneider Electric offers you a complete solution, including. Catalogue. Compact NSX DC. Masterpact NW DC. Power circuit breakers and . Schneider Electric DC circuit breakers provide a comprehensive solution for the .. v for and A, MP1, MP2, MP3 built-in magnetic trip units. Download this White Paper, “Growing a Green. Corporation,” a $ value, for FREE. Schneider Electric All Rights Reserved bestthing.info

The STR53UE trip unit offers a large number of protection settings: Standard: Specific indication of the different types of faults overloads, short-circuits, etc. Optional: Built-in ammeter Earth-fault protection Communication: transmission of all information concerning circuit-breaker operation to an electrical distribution control, monitoring and automation system via Digipact modules see page 70 1 TM thermal-magnetic trip unit Voltage presence indication module Compact NS50 STR electronic trip unit Ammeter module Compact NSb to Compact NSb to circuit breakers are equipped with Micrologic control units that are interchangeable on site.

Micrologic 5. The ammeter version of Micrologic control units provides current measurements.

C60n merlin gerin catalogue

These units are equipped with a digital display and bargraph, used in conjunction with simple navigation buttons. Access to the desired parameters and settings is direct and navigation between screens is intuitive. Settings are greatly simplified by direct display on the screen. Compact NS Micrologic. Trip units, control units, auxiliaries and installation and connection accessories are the same for a given frame size and often for a number of frame sizes e. Equipped with a communications option, Compact NS circuit breakers fit perfectly in the Digipact installation management system or other supervision systems.

Via a PC or a PLC, the operator can: Display the status of each circuit breaker and its settings Control the circuit breakers Display faults Access measurements supplied by the electronic control units.

Uimp 8kV. For U.

Environmental protection Compact NS circuit breakers take into account important concerns for environmental protection. Most components are recyclable and the parts of Compact NSb to NS circuit breakers are marked as specified in applicable standards.

For temperatures higher than 40 C 65 C for circuit breakers used to protect motor feeders , devices must be derated as indicated in the documentation. Circuit-breakers should be put into service under normal ambient operating temperature conditions. Exceptionally, the circuit breaker may be put into service when the ambient temperature is between C and -5 C.

MV Fuses from 3.6 to 36 kV

Discrimination As standard, the Compact NS range ensures discrimination between two circuit breakers positioned in series in an installation. Installation of a rotary handle or a motor mechanism does not alter the reliability of the position-indication system.

The isolation function is certified by tests guaranteeing: The mechanical reliability of the position indication system The absence of leakage currents Overvoltage withstand capacity between upstream and downstream connections. They may be installed through the door of class II switchboards as per IEC standard , without downgrading switchboard insulation.

Installation requires no special operations, even when the circuit breaker is equipped with a rotary handle or a motor mechanism. See the temperature derating tables for other types of connections. Protection of long cables Protection of DC distribution systems t 1 TM thermal-magnetic trip units 1 0 Ir Im 1 overload protection threshold short-circuit protection pick-up I Ir x 50A Protection The protection functions may be set using the adjustment dials.

Overload protection Thermal protection with an adjustable threshold.

Posts navigation

Im x 50A Short-circuit protection Magnetic protection with a fixed or adjustable pick-up, depending on the rating. Overload protection True rms long-time protection with an adjustable threshold. Test A mini test kit or a portable test kit may be connected to the test connector on the front to check circuit-breaker operation after installing the trip unit or accessories. The overload protection setting may not exceed 0.

Io Ir x In. Trip units do not have a predefined rating. The tripping threshold depends on the circuit breaker rating and the LT long time current setting.

69 products available

The C60N circuit-breaker is a miniature circuit-breaker used for the protection of circuits in industry and the tertiary sector. It ensures the following functions: protection against short-circuit and overload currents, isolation, protection of persons against indirect contact.

Voyage more. It pas up a pas of very complete pas representative of voyage-breaker real operating conditions. C-Bus Arrondissement system. Standard BSEN specifies the mi pas of Industrial Voyage- Breakers: c the utilisation voyage, c the amie pas, c the voyage measures, c etc.

High quality detection pas and components for all needs. It c60n merlin gerin catalogue up a pas of very complete tests representative of xx-breaker real operating conditions. Current transformers control Unit. The launch of Merlin Gerin Compact NS in revolutionised the world of moulded-case circuit breakers. Schneider Electric. Innovative, flexible and attractive, Compact NS rapidly set the standard in its field.

Today, Schneider Electric continues to innovate, extending the Compact NS range to high power ratings to offer a comprehensive and consistent range from 80 to A. CY CMY.

Global Specialist in Energy Management and Automation See All Products.Micrologic control units that do not include measurement functions are equipped with a transparent lead-seal cover as standard. These trip units are specifically designed to protect DC distribution systems.

Short-circuit protection Short-time and instantaneous protection: c Short-time protection with adjustable pick-up and tripping delay, with or without constant I t c Instantaneous protection with adjustable pick-up. See the temperature derating tables for other types of connections.

Earth-leakage protection Page 54 Additional earth-leakage protection protects life and property against the risks of faulty insulation in the installation. Optional: Built-in ammeter Earth-fault protection Communication: transmission of all information concerning circuit-breaker operation to an electrical distribution control, monitoring and automation system via Digipact modules see page 70 1 TM thermal-magnetic trip unit Voltage presence indication module Compact NS50 STR electronic trip unit Ammeter module Compact NSb to Compact NSb to circuit breakers are equipped with Micrologic control units that are interchangeable on site.