BUILDING CONSTRUCTION HANDBOOK PDF

adminComment(0)

The Building Construction Handbook is THE authoritative reference for all construction comprehensive and easy to understand guide to building construction. These are "selected'' or. "built in'' from the basic forms. I call the basic drawings “ Blooks,'' after myself. PART BUILDING DESIGN AND CONSTRUCTION. Concrete surface defects Part Seven Internal Construction and Finishes companion volume Building Services Handbook should be consulted for applica- .


Building Construction Handbook Pdf

Author:MAEGAN PELLITIER
Language:English, Japanese, Hindi
Country:Nicaragua
Genre:Science & Research
Pages:299
Published (Last):17.06.2015
ISBN:582-5-47631-462-2
ePub File Size:15.81 MB
PDF File Size:18.30 MB
Distribution:Free* [*Sign up for free]
Downloads:36912
Uploaded by: TRISH

Library of Congress Cataloging-in-Publication Data. Building design and construction handbook / Frederick S. Merritt, editor,. Jonathan T. Ricketts, editor. Download Building Construction Handbook By Roy Chudley And Roger Greeno – The Building Construction Handbook originated in as a series of four. BUILDING CONSTRUCTION HANDBOOK The Building Construction Handbook is THE authoritative reference for all construction students and professionals.

Please enter your comment! Please enter your name here. You have entered an incorrect email address! Get New Updates Email Alerts Enter your email address to subscribe this blog and receive notifications of new posts by email. Join With us. Today Updates. Punmia, Ashok Kumar Jain, Arun April 8. April 7. A Practical Course By S. April 4. Popular Files. January June Trending on EasyEngineering.

December May 1. February 7. Two sources of electrical supply to the site are possible: n n portable self-powered generators; metered supply from the local section of the national grid distribution network.

Item Preview

As a supply of electricity will be required in the final structure the second source is usually adopted, because it is generally possible to connect a permanent supply cable to the proposed development for construction operations, thus saving the cost of laying a temporary supply cable to the site.

To obtain a metered temporary supply of electricity a contract must be signed between the main contractor and a local area electricity marketing company. They will require the following information: n n n n n n Address of site.

Site location plan. Maximum anticipated load demand in kW for the construction period.

Final load demand of the completed building to ensure that the correct rating of cable is laid for the permanent supply. Date on which temporary supply will be required.

Name, address and telephone number of the building owner or their agent, and of the main contractor.

Electricity on building sites 23 To ensure that the supply and installation are available when required by the builder it is essential that an application for a temporary supply of electricity is made at the earliest possible date.

On any construction site it is possible that there may be existing electricity cables, which can be advantageous or may constitute a hazard or nuisance. Overhead cables will be visible, whereas the routes and depths of underground cables can be ascertained only from the records and maps kept by local area supply companies. Overhead cable voltages should be checked with the local area suppliers, because these cables are usually uninsulated and are therefore classed as a hazard due mainly to their ability to arc over a distance of several metres.

High-voltage cables of over 11 kV rating will need special care, and any of the following actions could be taken to reduce or eliminate the danger: n n n Apply to the local area supplier to have the cables re-routed at a safe distance or height.

Apply to have the cable taken out of service.

Erect warning barriers to keep site operatives and machines at a safe distance. These barriers must be clearly identified as to their intention, and they may be required to indicate the safe distance in both the horizontal and vertical directions. The local area supplier will advise on suitable safe distances according to the type of cable and the load it is transmitting. The position and depth of underground cables given by electricity suppliers must be treated as being only approximate, because historical records show only the data regarding the condition as laid, and since then changes in site levels may have taken place.

When excavating in the locality of an underground cable extreme caution must be taken, which may even involve careful hand excavation to expose the cable. Exposed cables should be adequately supported, and suitable barriers with warning notices should be erected.

Any damage, however minor, must be reported to the electricity supplier for the necessary remedial action. It is worth noting that if a contractor damages an underground electric cable that was known to be present, and possibly caused a loss of supply to surrounding properties, the contractor can be liable for negligence, trespass to goods and damages.

These impose duties and expectations on employers, employees and the self-employed, for health and safety responsibilities with regard to the use of electricity. Risk assessment and suitable precautions relating to particular hazards, such as overhead lines and underground cables encountered on site, are contained by the Health and Safety at Work etc.

[PDF] Building Construction Handbook Full Colection

Section details provision for temporary installations and installations on construction sites. See also, BS 24 Advanced Construction Technology Code of practice for distribution of electricity on construction and building sites. The supply distribution assemblies used in the installation should comply with the recommendations of BS Specification for distribution assemblies for reduced low voltage electricity supplies for construction and building sites.

This covers the equipment suitable for the control and distribution of electricity from a three-phase four-wire a. BS EN -2 specifies plugs, socket outlets and cable couplers for the varying voltages recommended for use on construction sites.

The appliances and wiring used in temporary installations on construction sites may be subject to extreme abuse and adverse conditions: therefore correct circuit protection, earthing and frequent inspection are most important, and this work, including the initial installation, should be entrusted to a qualified electrician or to a specialist electrical contractor. Electrical distribution cables contain three line wires and one neutral, which can give either a V three-phase supply or a V single-phase supply.

Records of accidents involving electricity show that the highest risk is encountered when electrical power is used in wet or damp conditions, which are often present on construction sites. It is therefore generally recommended that wherever possible the distribution voltage on building sites should be V. This is a compromise between safety and efficiency, but it cannot be overstressed that a supply of this voltage can still be dangerous and lethal.

The recommended voltages for use on construction sites are given below: Mains voltage V three-phase: n n supply to transformer unit, heavy plant such as cranes and movable plant fed via a trailing cable; hoists and plant powered by electric motors in excess of a 3.

11th Edition

Reduced voltage V three-phase: n n portable and hand-held tools; small mobile plant up to 3. It is worth considering the use of 50 or 25 V battery-supplied hand-lamps if damp situations are present on site.

Upcoming SlideShare. Like this presentation?

Why not share! An annual anal Embed Size px. Start on.

Building Construction Handbook (11th ed.)

Show related SlideShares at end. WordPress Shortcode. Published in: Full Name Comment goes here.

Are you sure you want to Yes No. Be the first to like this. No Downloads.

Views Total views.Table of Contents 1. General 2.

April 8. This new edition has been updated to reflect recent changes to the building regulations, as well as new material on the latest technologies used in domestic construction.

[PDF] Building Construction Handbook By Roy Chudley And Roger Greeno Book Free Download

Superstructure 2 7. English ISBN The principles and processes of construction are explained with the concepts of design included where appropriate. The principles and processes of construction are explained with the concepts of design included where appropriate.

DEONNA from Syracuse
Look over my other articles. I enjoy skittles. I relish shakily .
>