BS EN BRITISH STANDARD | | | | | Incorporating | | Amendment No. . prEN , Specifications for installations inside buildings conveying. BS EN was published in February at which point was BS EN – Specification for installations inside buildings conveying. View Account▹ · Home; BS EN Secure PDF. ℹ Printed Edition + PDF; Immediate download; $; Add to Cart.


Bs 806 Pdf

Author:ISABELLA DUENAS
Language:English, German, Japanese
Country:Morocco
Genre:Biography
Pages:566
Published (Last):04.02.2016
ISBN:306-7-20659-186-9
ePub File Size:22.83 MB
PDF File Size:14.87 MB
Distribution:Free* [*Sign up for free]
Downloads:34869
Uploaded by: NATHANIEL

BS EN and BS Throughout the United Kingdom, wholesome water ( i.e. water fit for human con- sumption) is provided by the local. BS - BS Band saws for hard and brittle materials. Most versatile machine for hard and brittle materials. Flexible application for small production volumes. BS EN - Download as PDF File .pdf), Text File .txt) or read online. Specifications for installations inside buildings conveying water for human.

Our policy towards the use of cookies Techstreet, a Clarivate Analytics brand, uses cookies to improve your online experience.

They were placed on your computer when you launched this website. You can change your cookie settings through your browser. Request Free Trial. Home BS EN Full Description Cross References: EN Other Browser: Production and conversion of electrical energy. Pipe sizing. ISO , Welding, and allied processes — Nomenclature of processes and reference numbers.

General rules and orthogonal representation.

ISO , Graphical symbols for diagrams — Part 3: Connections and related devices. ISO , Graphical symbols for diagrams — Part 4: Actuators and related devices. ISO , Graphical symbols for diagrams — Part 5: Measurement and control devices. ISO , Graphical symbols for diagrams — Part Basic mechanical components. Valves and dampers. Page 5 EN Page 6 EN The device may contain a service stop valve 5. A potable water installation that is under main's or boosted pressure 5.

A vented system is that part of the system, that is not under main's or boosted pressure 6 Graphic symbols and abbreviations For ease of reference, certain symbols are illustrated in Figure A.

NOTE Symbol infills may be solid or hatched. Page 9 EN ISO 6. The angle between the two parts is arbitrary. Unrestricted air gap AB: Air gap with overflow non-circular unrestricted AC: Air gap with submerged feed incorporating air inlet plus overflow AD: Air gap with injector AF: ISO AG: Air gap with overflow total by vacuum or measurement BA: Backflow preventer with controllable reduced pressure zone CA: Backflow preventer with different non controllable pressure zones DA: In line anti-vacuum valve DB: Pipe interrupter with atmospheric vent and moving element DC: Pipe interrupter with permanent atmospheric vent EA: Controllable antipollution check-valve EB: Non controllable anti pollution check-valve EC: Controllable anti pollution double check-valve ED: Non controllable anti pollution double check-valve GA: Fittings with compression ends for use with plastics pipes.

For undated references the latest edition of the referenced document including any amendments applies. Gas-fired central heating boilers — Specific requirements for the domestic hot water operation of combination boilers of nominal heat input not exceeding 70 kW. Plumbing fittings. Licensed copy: Part 4: Fittings combining other end connections with capillary or compression ends EN For dated references. Water supply — Requirements for external systems and components outside buildings.

Chemicals used for treatment of water intended for human consumption — Sodium chloride for regeneration of ion exchangers. Specifications for installations inside buildings conveying water for human consumption — Part 1: Ductile iron.

Gas-fired instantaneous water heaters for sanitary uses production.

Popular Publishers

Copper and copper alloys — Seamless. Uncontrolled Copy. Copper and copper alloys — Plumbing fittings — Part 2: Fittings with compression ends for use with copper tubes. Building valves — Pressure safety valves — Tests and requirements.

Building valves — Hydraulic safety groups —Tests and requirements. Plastics piping systems for water supply — Polyethylene PE — Part 1: General EN Protection of metallic materials against corrosion — Guidance on the assessment of corrosion likelihood in water distribution and storage systems — Part 1: Plastics piping systems for water supply — Polyethylene PE — Part 2: Pipes EN Protection of metallic materials against corrosion — Guidance on the assessment of corrosion likelihood in water distribution and storage systems — Part 2: Influencing factors for copper and copper alloys.

Non-Alloy steel tubes suitable for welding and threading — Technical delivery conditions. Building valves. Protection of metallic materials against corrosion — Guidance on the assessment of corrosion likelihood in water distribution and storage systems — Part 3: Influencing factors for hot dip galvanised ferrous materials. Building valves — Expansion valve — Tests and requirements. Pipe threads where pressure tight joints are made on the threads. Tests and requirements.

Combined temperature and pressure relief valves.

Plastics piping systems for water supply — Polyethylene PE — Part 7: Guidance for the assessment of conformity. Plastics piping systems for water supply — Polyethylene PE — Part 5: Fitness for purpose of the system. ENV Protection of metallic materials against corrosion — Guidance on the assessment of corrosion likelihood in water distribution and storage conveying systems — Part 4: Influencing factors for stainless steels.

Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow.

Building valves — Expansion group — Tests and requirements. Plastics piping systems for water supply — Polyethylene PE — Part 3: Malleable cast iron fittings with compression ends for polyethylene PE piping systems.

You might also like: ISO 9001 NORM PDF

Threaded pipe fitting in malleable cast iron. Part 1: Taper external threads and parallel internal threads. Protection of metallic materials against corrosion — Guidance on the assessment of corrosion likelihood in water distribution and storage systems — Part 5: Influencing factors for cast iron.

EN ISO Mechanical filters. Part 3: Mounting and operating conditions for in-line valves and appliances ISO Plastics piping systems for hot and cold water installations — Polypropylene PP — Part 3: Fittings ISO Automatic electrical controls for household and similar use — Part Particular requirements for electrically operated water valves.

Laboratory tests on noise emission from appliances and equipment used in water supply installations. Requirements for performance. Part 2: Mounting and operating conditions for draw-off taps and mixing valves ISO Soft solder alloys. Part Particular requirements for storage water heaters IEC Fibre — cement. Industrial-process control valves — Part 8: Noise considerations — Section 4: Plastics piping systems for hot and cold water installations— Polypropylene PP — Part 7: Automatic electrical controls for household and similar use — Part 1: General requirements IEC Method of measurement ISO Plastics piping systems for hot and cold water installations — Polypropylene PP — Part 2: Pipes ISO Household and similar electrical appliances -Safety.

Corrosion of metals and alloys. Electrolytic treatment systems with aluminium anodes Requirements for performance.

Ductile iron wide tolerance couplings and flange adaptors for use with pipes of different materials: Mounting and operating conditions for special appliances ISO Plastics piping systems for hot and cold water installations — Polypropylene PP — Part 5: Fitness for purpose of the system ISO Grey iron.

Water conditioning equipment inside buildings. Water equipment inside buildings. Requirements for performances. Plastics piping systems for hot and cold water installations — Polypropylene PP — Part 1: General ISO Determination Particular requirements for instantaneous water heaters IEC Household and similar electrical appliances.

Earthing arrangements. Plastics piping systems for hot and cold water installations — Polybutylene PB — Part 7: Plastics piping systems for hot and cold water installations— Crosslinked polyethylene PE-X — Part 7: Plastics piping systems for hot and cold water installations — Crosslinked polyethylene PE-X — Part 1: Plastics piping systems for hot and cold water installations — Crosslinked polyethylene PE-X — Part 3: Electrical installations of buildings.

BS EN 806-3:2006

ISO IEC Plastics piping systems for hot and cold water — Polybutylene PB — Part 1: Plastics piping systems for hot and cold water installations — Polybutylene PB — Part 2: Plastics piping systems for hot and cold water installations — Polybutylene PB — Part 3: Plastics piping systems for hot and cold water installations — Crosslinked polyethylene PE-X — Part 2: Plastics piping systems for hot and cold water installations — Crosslinked polyethylene PE-X — Part 5: Selection and erection of electrical equipment.

Attention is drawn to national or local regulations and requirements. Plastics piping systems for hot and cold water installations — Polybutylene PB — Part 5: The design and selection of materials shall take into consideration the service conditions and water quality. Where these are not available national standards or local regulations should be used.

Figure 2. Vented potable water installations. Information and criteria about the reasonable choice of metal pipe material taking into account corrosion likelihood is given in EN to —5.

Unless otherwise specified in European Standards. Installation types A and B may be combined. The potable water installation shall be designed to: Closed potable water installations. Figure 3. All pipes and joints of a potable water installation shall be designed for a service life of 50 years taking into account appropriate maintenance and specific operating conditions.

The test pressure shall be at least 1. Surge pressures resulting from the operation of valves in fire extinguishing and fire protection systems which are operated no more than once a month for test purposes and otherwise only in the event of a fire are excluded from this requirement.

There shall be no cross connection of systems carrying water from different water suppliers or of different sources from one supplier. If not required in national or local regulations the sum of operation pressure and surge pressure should not exceed test pressure of the installation. See EN Lead pipes and -fittings shall not be used.

Pipe joints shall be permanently water-tight under the alternating stresses occurring in operation. Basically two different designs will be distinguished: Other materials and systems can be used if they comply with the general requirements given in 3. For the latter. Thread according to EN b Thread on transition fittings c See national regulations and standards d Corrosion risks have to be considered. Sockets with spigot ends according to EN Copper alloy compression fittings.

BS 8558 provides complementary guidance to BS EN 806

Pipes see EN Copper and copper alloy capillary fittings for soldering and brazing. Galvanized malleable cast iron fittings are normally used for jointing. Protective coatings and linings may be required. For push fit fittings see prEN For threaded ends see EN Fluxes containing chlorides. Hot dip galvanized malleable cast iron fittings according to EN Small copper connections to large stainless steel tanks should be avoided.

Solders shall be tin copper alloy No Site formed bends shall not be used to avoid damage to galvanizing. EN Pipes. Further statements Pipes. Only joints with fitness for purpose of the PE-piping system according to EN Socket fittings according to EN X - permissible not permissible Only joints with fitness for purpose of the PE-piping system according to EN Only joints with fitness for purpose of the PEpiping system according to EN X permissible - not permissible Pipes.

Hoses should not be longer than 2. In addition. This stop valve shall. A servicing valve shall be provided on the inlet connection to appliances e.

The supply pipes for each storey and those in the individual flats shall be capable of being shut off separately. This stop valve shall be installed either inside or outside the building in a position to which every occupier of the premises supplied has access.

Proof of compliance with this requirement shall be provided by the manufacturer. In every building or part of a building to which a separately chargeable supply of water is provided and in all premises occupied as a dwelling.

This stop valve shall be located in the main building as near as practicable to the exit point of the supply pipe to the other structure or if this is not practicable in the other structure itself as near as possible to the point of entry of the supply.

All hoses used instead of pipes and which are permanently under pressure shall comply with 3. The applicable test method should be agreed between the manufacturer and the customer. Elastomeric expansion joints shall have a minimum lifetime of 10 years when fitted according to manufacturers instructions.

The use of elastomeric expansion joints in a potable water system is only permitted if they have been suitably approved implying their adequacy of design and material. Pipes shall not be laid through drains or sewers. Pipework may be boxed in. Where a supply provides water to more than one building a riser shall be installed in each building.

In the case where less frequent use is made of the draw off capacity. Fire protection has to be maintained. Except where a pipe is installed in a sleeve. In a dwelling divided into a number of flats. If colour code is used for this purpose. Pipe runs to cold water taps within buildings shall not follow the routes of space heating or hot water pipes or pass through heated areas such as airing cupboards or.

Where pipes for hot and cold potable water are arranged one above another. Special measures e. Draining taps should be fixed over a drain or have provision for discharging the water to the nearest convenient point for disposal. The pipework within each building shall be connected to potential equalizing bars. Draw-off points for non-potable water shall be identified with the words "Non-potable water" or by a prohibition sign as shown in figure 1.

Water outlets shall only be placed in positions where there is a drainage system of sufficient capacity. A servicing valve shall be fitted upstream of.Their performances are related to the specific membrane characteristics and operating conditions nano filtration. Direct Navigation IP: Chemicals used for treatment of water intended for human consumption — Sodium chloride for regeneration of ion exchangers. Copper and copper alloys. Various BSI electronic information services are also available which give details on all its products and services.

An inspection should be carried out to identify any obvious leaks within the system under test. Pressurised air inlet valve combined with a check valve located downstream 6. Method for measuring the rate of heat release of products BS - Current Fire tests on building materials and structures.